Rotary pump & chiller acoustic boxes overview
silentLab acoustic enclosures for rotary pumps and recirculating chiller / heaters
Effective noise reduction for rotary vacuum pumps and water chillers
silentLab acoustic enclosures are especially designed to reduce the noise level generated by vacuum pumps and water chillers used with SEMs, TEMs, FIB-SEMs, sample preparation instruments and other analytical systems.
If it is not possible to locate vacuum pumps and/or the water chiller to a separate room, the noise level generated can be irritating and distracting. Using a silentLab acoustic enclosure will significantly reduce noise to an acceptable level and allow operators to concentrate on the task at hand. silentLab acoustic enclosures are sophisticated and safe soundproofing boxes which are placed over the noisy vacuum pump or water chiller. They facilitate power and vacuum pumping lines, provide cooling and will allow vacuum pumps or water chillers operate at their full specifications.
silentLab models 4, 6 and 7 were originally designed for SEMs, TEMs and FIB-SEM systems, but they are equally useful for other systems with noisy rotary vacuum pumps. silentLab 3 has been specifically designed for smaller pumps used with SEM sputter coaters, EM carbon coaters, RF plasma etcher/asher/cleaners and vacuum ovens. silentLab 5 is intended for analytical systems with larger noisy rotary vacuum pumps.
silentLab noise reduction enclosures features:
-
- Noise reduction approximately 15dB to 12dB, depending on type
- Robust all-metal construction with high performance acoustic foam
- Acoustic foam with optimised pattern to reduce low frequency noise
- IEC mains connectors with fuse for easy installation
- Fans are only switched on when the rotary pump is running
- Sophisticated air flow system with low noise high capacity fans
- Integrated digital thermometer
- Top lid for easy service access
- Powder-coated oil and water resistant surface
- Flammability rating to DIN 75200 / FMVSS 302
- Internal KF25 installation kit included
silentLab specifications and selection guide
Model |
silentLab 3 |
silentLab 4 |
silentLab 5 |
silentLab 6 |
silentLab 7 |
Noise reduction | 12dB | 15dB | 15dB | 12dB | 12dB |
Designed for | Small rotary pump
|
Single rotary pump | Large single rotary pump | Two rotary pumps | Water chiller |
Compatible with (similar to) |
Pfeiffer UNO 5 Pfeiffer DUO 5 Edwards RV5 Alcatel BB2002 Edwards E2M1.5 |
Edwards RV12 / RV18 Edwards XDS10 / nXDS10 Adixen/Varian/Agilent2010L |
Edwards E2M28 Adixen 2033SD Pfeiffer DUO 20M |
2 x Edwards RV12 2 x Adixen 2010L |
V.d. Heyden 004 |
Fans | 2 | 2 | 2 | 4 | 4 |
Voltage | 230/115V | 230V / 115V | 230V / 115V | 230V / 115V | 230V / 115V |
Power rating | Fused 2300W | Fused 2300W | Fused 2300W | Fused 2300W | Fused 2300W |
Power connections | IEC sockets | IEC sockets | IEC sockets | IEC sockets | IEC sockets |
Outside dimensions | 350 x 400 x 600mm | 500 x 500 x 800mm | 500 x 500 x 900mm | 500 x 500 x 800mm | 800 x 900 x 850mm |
Inside dimensions | 250 x 350 x 500mm | 400 x 450 x 700mm | 400 x 450 x 800mm | 440 x 450 x 740mm | 530 x 580 x 740mm |
Weight | 16kg | 20kg | 23kg | 20kg | 35kg |
Product # | 60-001030 (230V) 60-001031 (115V) |
60-001040 (230V)
60-001041 (115V) |
60-001050 (230V)
60-001051 (115V) |
60-001060 (230V) 60-001061 (115V) |
60-001070 (230V)
60-001071 (115V) |
Ordering information:
-
SilentLab 3 for small single rotary pump – 230V
SilentLab 3 for small single rotary pump – 230V (each)
£2,143.42 Add to basket -
SilentLab 4 for single rotary pump – 230V
SilentLab 4 acustic enclosure for a single rotary pump, 230V (each)Featuring:• Noise reduction approximately 15dB to 12dB• Robust all-metal construction with high performance acoustic foam• Acoustic foam with optimised pattern to reduce low frequency noise• IEC mains connectors with fuse for easy installation • Fans only switched on when the rotary pump is running• Sophisticated air flow system with low noise high capacity fans• Integrated digital thermometer• Top lid for easy service access• Powder-coated oil and water resistant surface in light blue RAL5005• Flammability rating to DIN 75200 / FMVSS 302• Internal KF25 installation kit included
£2,674.36 Add to basket -
SilentLab 5 for large single rotary pump – 230V
SilentLab 5 for large single rotary pump, 230V (each)Featuring:• Noise reduction approximately 15dB to 12dB• Robust all-metal construction with high performance acoustic foam• Acoustic foam with optimised pattern to reduce low frequency noise• IEC mains connectors with fuse for easy installation• Fans only switched on when the rotary pump is running• Sophisticated air flow system with low noise high capacity fans• Integrated digital thermometer• Top lid for easy service access• Powder-coated oil and water resistant surface in light blue RAL5005• Flammability rating to DIN 75200 / FMVSS 302• Internal KF25 installation kit included
£2,675.33 Add to basket -
SilentLab 6 for two rotary pumps – 230V
SilentLab 6 for two rotary pumps- 230V (each)
£3,080.84 Add to basket -
SilentLab 7 for water chiller 530 x 580 x 740mm – 230V
SilentLab 7 for water chiller 530 x 580 x 740mm – 230V (each)
£3,949.79 Add to basket